Drilling Pumpwire
Paige Pumpwire Logo

Paige Submersible Pumpwire
Water Well/Flat-Plastic Cables


Flat-Unarmored Plastic Cables conductor pumpwire
3/C with Ground THHN/PVC Power & Control Submersible Pump Cable
VOLTAGE:
600V
INSULATION: PVC - Polyvinyl Chloride
OUTER JACKET: PVC - Polyvinyl Chloride
INSULATION JACKET: Nylon
SIZES: 14 AWG - 500 MCM, 2 & 3 Conductor with ground
TEMP DRY/WET: 90°C Dry, 75°C Wet
SCOPE: Heavy Duty, (double jacketed) Flat, Submersible pump cable suitable for use within well casings
for wiring deep well fresh or salt water submersible pumps.
APPROVALS: UL LOGO    RoHs Logo


Flat-Unarmored Plastic pumpwire
3/C THHN/PVC Power & Control
Submersible Pump Cable

VOLTAGE:
600V
INSULATION: PVC - Polyvinyl Chloride
OUTER JACKET: PVC - Polyvinyl Chloride
INSULATION JACKET: Nylon
SIZES: 12 - 500 AWG, 3 Conductor
TEMP DRY/WET: 90°C Dry, 75°C Wet
SCOPE: Heavy Duty, (double jacketed) Flat, Submersible pump cable suitable for use within well casings
for wiring deep well fresh or salt water submersible pumps.
APPROVALS: UL LOGO    RoHs Logo


Flat-Unarmored Plastic pumpwire
1000 Volt 3/C no Ground XLPE/PVC
VOLTAGE:
1000
INSULATION: XLPE - Cross-Linked Polyethlene
OUTER JACKET: PVC - Polyvinyl Chloride
SIZES: 8 AWG - 2 AWG
TEMP DRY/WET: 90°C Dry, 75°C Wet
SCOPE: 1000 volt, Heavy Duty Flat pump cable three conductors without ground suitable for use within well casings for wiring deep well fresh or salt water submersible pumps.
APPROVALS:  RoHs Logo   RoHs Logo   RoHs Logo


Flat-Unarmored Plastic pumpwire

3/C with Ground Tested Good for 2.4kV per NEC XLPE/PVC Submersible Pump Cable
VOLTAGE:
5000V
INSULATION: XLPE - Cross-Linked Polyethlene
OUTER JACKET: PVC - Polyvinyl Chloride
SIZES: 6 AWG - 2/0
TEMP DRY/WET: 90°C Dry, 90°C Wet
SCOPE: Flat 5000v submersible pump cable with cross-linked XLPE insulated circuit and grounding conductors and an overall PVC jacket. Tested and rated for up to 2.4kV per NEC. Suitable for use within well casings for wiring deep-well submersible water pumps.
APPROVALS:  UL LOGO    RoHs Logo


Flat-Unarmored Plastic Cables conductor pumpwire
3/C with Ground THHN/PVC Power & Control Submersible Pump Cable
VOLTAGE:
600V
INSULATION: PVC - Polyvinyl Chloride
OUTER JACKET: PVC - Polyvinyl Chloride
INSULATION JACKET: Nylon
ARMOR: Galvanized Steel
SIZES: 14 - 500 MCM, 2 & 3 Conductor without Ground
TEMP DRY/WET: 90°C Dry, 75°C Wet
SCOPE: Heavy Duty, (double jacketed) Flat, Submersible pump cable with flat armor suitable for use within well casings for wiring deep well fresh or salt water submersible pumps where maximum mechanical protection is desired.
APPROVALS: UL LOGO    RoHs Logo